H07RN-F, HAR, connection and control cable Rubber, heavy, 450 / 750V, for industry and Agriculture, class 5 / flexible-25 ° C to + 60 ° C, oil-resistant, flame-retardant. Please select the cable length. The cables are made to order. A withdrawal or withdrawal from the purchase is excluded! All product photos are non-binding examples! Technical changes reserved.
M25 cable gland brass, EMC-Z - Suitable for shielded control cables up to 4 x 2.5 mm² - for cables with a diameter of 7 mm to 13 mm - Brass cable gland with low-resistance shield contact - Highly conductive, flexible EMC contact spring - Easy construction
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid.Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter approx.12.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid. Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 11.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!
Suitable for frequency inverters CPR performance class: Eca, conductor material: Cu, bare conductor class: class 5 = finely stranded, core insulation: PVC TI1 stranding element: core, sheath material: PVC YM2 sheath color: gray RAL 7001, flame retardant : VDE 0482-332-1-2 / IEC 60332-1-2 Maximum permissible conductor temperature: 70 ° C Perm. External cable temperature fixed: -40 - +70 ° C Perm. Outside cable temperature, in motion -5 - +70 ° C bending radius, fixed installation: 6 x Ø, bending radius, moving: 20 x Ø nominal Voltage Uo: 300 V, nominal Voltage U: 500 V core identification: green -yellow + digits cable diameter approx. 10.1 mm Please select the cable length and the equipment. All product photos are non-binding examples! Technical changes reserved.
M20 cable gland brass, EMC-Z - Suitable for shielded control cables up to 4 x 2.5 mm² - for cables with a diameter of 7 mm to 13 mm - Brass cable gland with low-resistance shield contact - Highly conductive, flexible EMC contact spring - Easy construction
Flexible connection cable with Schuko plug Voltage= 1x 230VCable= H07RN-F 3x1.5 mm²,Length= 5 meters (Image only product example)
M32 cable gland brass, EMC-Z - Suitable for shielded control cables up to 4 x 2.5 mm² - for cables with a diameter of 7 mm to 13 mm - Brass cable gland with low-resistance shield contact - Highly conductive, flexible EMC contact spring - Easy construction
M40 cable gland brass, EMC-Z - Suitable for shielded control cables up to 4 x 2.5 mm² - for cables with a diameter of 7 mm to 13 mm - Brass cable gland with low-resistance shield contact - Highly conductive, flexible EMC contact spring - Easy construction
M50 cable gland brass, EMC-Z - Suitable for shielded control cables up to 4 x 2.5 mm² - for cables with a diameter of 7 mm to 13 mm - Brass cable gland with low-resistance shield contact - Highly conductive, flexible EMC contact spring - Easy construction
EMC-optimized cable between frequency converter and motor, low capacity, double shielded. The shielding consists of an aluminum-coated foil wrapping combined with tinned copper braid. Technical data: classification ETIM 5: ETIM 5.0 Class-ID: EC000057 ETIM 5.0 Class-Description: power cable classification ETIM 6: ETIM 6.0 Class-ID: EC000057 ETIM 6.0 Class Description: Power Cables and Core Ident Code: Colored acc. HD 308 S2 VDE 0293-308 Conductor structure: Fine wire according to VDE 0295 Class 5 / IEC 60228 Class 5 Minimum bending radius: Occasionally moving: 15 x outer diameter Fixed installation: 4 x outer diameter and nominal Voltage : U0 / U: 600/1000 V test Voltage: wire / wire: 4 kV wire / screen: 4 kV temperature range: moving: -5 ° C to + 70 ° C fixed installation : -40 ° C to + 70 ° C PVC outer sheath: transparent cable diameter approx. 12.4 mm Please select the cable length. The cables are made to order. A withdrawal or withdrawal from the purchase is excluded! All product photos are non-binding examples!
Flexible connection cable with CEE 16A plug including phase inverter Voltage= 3x 400VCable= H07RN-F 5x1.5 mm²,Length= 5 meters All product photos are non-binding examples! Technical changes reserved.
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid.Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 53.2 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!
EMC-optimized cable between frequency converter and motor, low capacity, double shielded. The shielding consists of an aluminum-coated foil wrapping combined with tinned copper braid. Technical data: classification ETIM 5: ETIM 5.0 Class-ID: EC000057 ETIM 5.0 Class-Description: power cable classification ETIM 6: ETIM 6.0 Class-ID: EC000057 ETIM 6.0 Class Description: Power Cables and Core Ident Code: Colored acc. HD 308 S2 VDE 0293-308 Conductor structure: Fine wire according to VDE 0295 Class 5 / IEC 60228 Class 5 Minimum bending radius: Occasionally moving: 15 x outer diameter Fixed installation: 4 x outer diameter and nominal Voltage : U0 / U: 600/1000 V test Voltage: core / core: 4 kV core / shield: 4 kV temperature range: moving: -5 ° C to + 70 ° C fixed installation : -40 ° C to + 70 ° C PVC outer sheath: transparent cable diameter approx. 22.1 mm Please select the cable length. The cables are made to order. A withdrawal or withdrawal from the purchase is excluded! All product photos are non-binding examples!
EMC-optimized cable between frequency converter and motor, low capacity, double shielded. The shielding consists of an aluminum-coated foil wrapping combined with tinned copper braid. Technical data: classification ETIM 5: ETIM 5.0 Class-ID: EC000057 ETIM 5.0 Class-Description: power cable classification ETIM 6: ETIM 6.0 Class-ID: EC000057 ETIM 6.0 Class Description: Power Cables and Core Ident Code: Colored acc. HD 308 S2 VDE 0293-308 Conductor structure: Fine wire according to VDE 0295 Class 5 / IEC 60228 Class 5 Minimum bending radius: Occasionally moving: 15 x outer diameter Fixed installation: 4 x outer diameter and nominal Voltage : U0 / U: 600/1000 V test Voltage: wire / wire: 4 kV wire / screen: 4 kV temperature range: moving: -5 ° C to + 70 ° C fixed installation : -40 ° C to + 70 ° C PVC outer sheath: transparent cable diameter approx. 26.3 mm Please select the cable length. The cables are made to order. A withdrawal or withdrawal from the purchase is excluded! All product photos are non-binding examples!
Your partner in the field of drive technology
JS-Technik GmbH is your specialist in the field of professional drive technology. We specialise in three-phase motors, frequency inverters and geared motors. You can order our drives as energy-saving motors in IE2/IE3 and also in IE4 on request. In many cases, electric motors with specific requirements and corresponding accessories are needed. We are the ideal partner for you here, as we can offer you a wide range of motor variants thanks to our specialised staff in combination with an extensive motor warehouse and our own final assembly.
Power connection
We have often been asked about connection cables for electric motors, frequency inverters or our geared motors offered here in the shop. We have therefore decided to expand our range so that you can order additional accessories for your drive or control unit. If you require special versions, please enquire.