- Imprint
- Online Calculator
- Download
Frequency inverter 0.4kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 150 x 276 x 192 mm- Weight: 3.3 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 0.75kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 150 x 276 x 192 mm- Weight: 3.5 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 1.5kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 150 x 276 x 192 mm- Weight: 3.5 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 2.2kW, 3 x 400 Volt, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 150 x 276 x 192 mm- Weight: 3.6 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 4.0kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 150 x 276 x 192 mm- Weight: 3.7 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 5.5kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 180 x 310 x 225 mm- Weight: 5.3 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 7.5kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 180 x 310 x 225 mm- Weight: 5.6 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 11kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 200 x 355 x 225 mm- Weight: 7.6 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 15kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 200 x 355 x 225 mm- Weight: 7.7 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 18.5kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 240 x 424 x 265 mm- Weight: 13.6 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 22kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 240 x 424 x 265 mm- Weight: 14 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 30kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 260 x 500 x 271 mm- Weight: 18.6 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 37kW, 3 x 400 volts, built-in dynamic braking transistor, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 260 x 500 x 271 mm- Weight: 18.7 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 45kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 300 x 510 x 299 mm- Weight: 28.3 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 55kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 350 x 615 x 318.3 mm- Weight: 41.2 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 75kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 350 x 615 x 318.3 mm- Weight: 41.9 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 90kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 306.4 x 725 x 391 mm- Weight: 58 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 110kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 306.4 x 725 x 391 mm- Weight: 58 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 132kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 386.4 x 724 x 401 mm- Weight: 77 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 160kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 386.4 x 724 x 401 mm- Weight: 78 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 185kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 426 x 920 x 441 mm- Weight: 120.5 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.
Frequency inverter 220kW, 3 x 400 Volt, LED control panel, Control method - V/F- V/F with slip compensation- V/F with pulse generator (PG) - Sensorless vector control- Vector control with encoder- Optimised motor control Frequency resolution and accuracy - Digital: 0.01 Hz- Analogue: ±0.06 Hz at 60 Hz (typical) Overload capability Normal Duty (ND):- 200 V class up to 45 kW: 120 % for 1 minute- from 55 kW: 110 % for 1 minute Heavy Duty (HD):- 150 % for 1 minute compared to the rated current- STO safety function Integrated two-channel safe torque off function (STO) Space-saving design- 10-40 % smaller size depending on capacity- Integrated DC reactor and EMC filter for all capacities- Dimensions (W x H x D): 426 x 920 x 441 mm- Weight: 121.5 kgPredictive maintenance- Predicts and evaluates the service life of the main capacitor, fan and relayUser-friendly- Intelligent LCD display- Simple creation of user sequencesAll product photos are non-binding examples! Subject to technical changes.